Axial Flow Roof Mounted Fans – Zet-Afro https://zetafro.com Zet-Afro Business Ventures Limited Sun, 05 Mar 2023 11:58:54 +0000 en-US hourly 1 https://wordpress.org/?v=6.5.5 https://zetafro.com/wp-content/uploads/2023/03/cropped-site-icon-32x32.png Axial Flow Roof Mounted Fans – Zet-Afro https://zetafro.com 32 32 Roof Mounted Axial Flow Fans HGHT-V Series https://zetafro.com/product/roof-mounted-axial-flow-fans-hght-v-series-2/ https://zetafro.com/product/roof-mounted-axial-flow-fans-hght-v-series-2/#respond Sun, 05 Mar 2023 11:58:03 +0000 https://zetafro.com/?post_type=product&p=2049

HGHT-V

Range of roof mounted axial flow fans, with vertical air discharge configuration, for air extract.
Designed for smoke extraction in fi re conditions and certified F400-120 and F300-120 (HGHT-V – CE marked).
Casing formed from rolled sheet steel welded on the base with a corrosion resistant hot dipped galvanized finish. High grade die-cast aluminum blades locked within a pressed sheet steel hub. Backdraft shutter and proof guard at the fan discharge. Cylindrical casing formed from rolled sheet steel protected against corrosion by grey polyester paint coating.

Motors
– HGHT-V F400-120: three-phase 4 pole motors 400V-50Hz, IP55, class H insulation.
– HGHT-V: F300-120: three-phase 4 pole motors 400V-50Hz, IP55, class H insulation.
– Electrical isolator fitted to fan casing.
Three phase 230/400V-50Hz up to 3 kW.
Three phase 400V-50Hz, for higher power motors and two speed motors.
(See characteristics chart).

Additional Information
Standard air direction: form (A)configuration (Motor over impeller).

On request
– 6 pole motors.
– 2 speed motors 4/6 and 4/8 poles.

Attributes

  • HGHT-Vbdp506

    Isolator
    Electrical isolator.

  • HGHT-Vbdp487

    Outlet guard
    Outlet guard protection.

  • HGHT-Vbdp481

    Support base
    Base for roof installation.

  • HGHT-Vbdp531

    Inlet flange
    Flange for duct connection or bellmouth inlet.

  • HGHT-Vbdp501

    Form (A) configuration
    Standard air direction: form (A) configuration (Motor over impeller).

  • HGHT-Vbdp496

    Web support
    To strengthen base support. Model 1250 only.

  • HGHT-Vbdp549

    Back draft shutter
    Prevent back draft of air and entrance of rain water when the fan is switched off.

]]>
https://zetafro.com/product/roof-mounted-axial-flow-fans-hght-v-series-2/feed/ 0
Roof Mounted Axial Flow Fans HGTT-V Series https://zetafro.com/product/roof-mounted-axial-flow-fans-hgtt-v-series/ https://zetafro.com/product/roof-mounted-axial-flow-fans-hgtt-v-series/#respond Sun, 05 Mar 2023 11:58:03 +0000 https://zetafro.com/?post_type=product&p=2050

HGTT-V

Range of roof mounted axial flow fans, with vertical air discharge configuration, for air extract.
Casing formed from rolled sheet steel welded on the base with a corrosion resistant hot dipped galvanized finish. High grade die-cast aluminum blades locked within a pressed sheet steel hub. Backdraft shutter and bird proof outlet. Cylindrical casing formed from rolled sheet steel protected against corrosion by grey polyester paint coating.

Motors
– HGTT-V: Three-phase 4 pole motors 400V-50Hz, IP55, class F insulation:
220-240/380-415V-50Hz up to 3 kW.
380-415V-50Hz, for higher power motors and two speed motors.
(See characteristics chart).
– Electrical isolator fitted to fan casing.

Additional information
Standard air direction: form (A) configuration (Motor over impeller).

On request
6 pole motors.
2 speed motors 4/6 and 4/8 poles.

Attributes

  • HGTT-Vbdp506

    Isolator
    Electrical isolator.

  • HGTT-Vbdp487

    Outlet guard
    Outlet guard protection.

  • HGTT-Vbdp481

    Support base
    Base for roof installation.

  • HGTT-Vbdp531

    Inlet flange
    Flange for duct connection or bellmouth inlet.

  • HGTT-Vbdp501

    Form (A) configuration
    Standard air direction: form (A) configuration (Motor over impeller).

  • HGTT-Vbdp496

    Web support
    To strengthen base support. Model 1250 only.

  • HGTT-Vbdp549

    Back draft shutter
    Prevent back draft of air and entrance of rain water when the fan is switched off.

]]>
https://zetafro.com/product/roof-mounted-axial-flow-fans-hgtt-v-series/feed/ 0
Roof Mounted Axial Flow Fans HCTB / HCTT Series https://zetafro.com/product/roof-mounted-axial-flow-fans-hctb-hctt-series-2/ https://zetafro.com/product/roof-mounted-axial-flow-fans-hctb-hctt-series-2/#respond Sun, 05 Mar 2023 11:58:03 +0000 https://zetafro.com/?post_type=product&p=2051

HCTB/HCTT

Range of axial roof fans with horizontal air discharge configuration available in 2 version:
-“B” models for air extract.
-“A” models for air supply.
Base manufactured from galvanized sheet steel.
Cowl manufactured from spun aluminium. The impellers for models 315 to 400 are manufactured from one piece injection moulded plastic, reinforced with chemical anchored fibreglass for additional strength. Models 450 to 1000 incorporate separate plastic blades locked within a die cast aluminium hub.
Available, depending upon the model, with single or three phase motors in 4, 6, 8 or 4/8 poles.

Motors
All motors are IP65 (1) Class F (2) with thermal protection (3) and ball bearings greased for life.
Electrical supply:
-Single phase 230V-50Hz (Capacitor located inside the wiring terminal box).
-Three phase 400V-50Hz.
(See characteristics chart).
All single phase models are speed controllable by voltage except HCTB/4- 560, HCTB/4-630.
All three phase models are speed controllable by autotransformer, except models HCTT/4- 560, HCTT/4-630, Ø 710 to 1000.
Three phase models, 1 speed motor, are speed controllable by inverter.
(1) 800 to 1000 models are IP55.
(2) Air stream temperature limits -40ºC to +70ºC (except models 800 to 1000 suitable for usage in environments from -20ºC to 40ºC).
(3) 800 to 1000 models are not equipped with thermal protection.

Aplications
Industrial process ventilation, agricultural facilities, swimming pools and data centers.

ATEX

HCTT ATEX
ATEX versions available for 3 phase models. For ambient working temperatures from -20ºC to +40ºC.
Motors IP55, class F.
– ATEX Flameproof – Gas
Only available for 800 to 1000 models
II 2G Ex d IIB T4<br<II 2G Ex d IIB+H2 T4 (with motor Ex d IIC T4)
– ATEX Increased safety – Gas
II 2G Ex e II T3
– ATEX – Dust
Only available for 800 to 1000 models
Suspended flammable particles and non-conductive dust:
II 3D Ex tc IIIB T125ºC
Conductive dust:
II 3D Ex tc IIIC T125ºC (with IP65 motor)
To select HXTT ATEX refer to performance data or EASYVENT.
Note electrical data may vary for ATEX motors.</br<

Attributes

  • HCTB/HCTTbdp506

    Easy to install
    Supports to facilitate installation in the roof.

  • HCTB/HCTTbdp487

    High quality steel sleeve
    Ensuring the long life of the fan.

  • HCTB/HCTTbdp481

    Impeller dynamically balanced
    Impellers are dynamically balanced, according to ISO 1940 standard, giving vibration free operation.

  • HCTB/HCTTbdp531

    Bird-proof guard.

]]>
https://zetafro.com/product/roof-mounted-axial-flow-fans-hctb-hctt-series-2/feed/ 0